YLWS- □ □ 0- □- □
① ② ③ ④
①Display selection ②Humidity selection ③Program selection
④Additional function selection 0:No humidity detection control -P:30 program
1:Nixie tube display 1:Humidity detection control Empty: fixed value
T1:485Communication
Product features:
1、Program or fixed value control: Microcomputer program control temperature, humidity, can be set to 24 program control or constant value control.
2、The number of operation segments and operation time can be adjusted manually:24 sections of the program can be arbitrarily selected to run several sections, after the end of the last section can be repeated from the first section, you can set the number of repeated running.The number of running segments and time can be manually modified through the combination of keys. Using this method, the running time of the controller can be adjusted to be synchronized with Beijing time.
3、Power on mode selection:During power-on, you can select the power-on state to stop.Either from the first section or from the last power failure.
4、Ultraviolet disinfection function:The lighting output can be set as UV lamp disinfection output through parameter setting.
5、Rich protection function: 2 level temperature alarm protection, humidification condition protection, refrigeration protection, temperature fault alarm or measurement beyond the range of alarm, etc., perfect protection function to ensure the safe operation of the experiment without accidents.
6、Balanced or start-stop control:Through parameter setting, you can select balanced temperature and humidity control or start stop temperature and humidity control.Balance type control temperature and humidity can start the temperature or humidity self-tuning to more accurately control the temperature (+-0.1 degree) and humidity (+-1%), balance type has defrosting output options.Compressor refrigeration dehumidification control with independent intellectual property rights start and stop program, regardless of winter or summer, set high temperature and low temperature, high humidity and low humidity, set light intensity and so on,light intensity and so on, the start-stop control basically does not need to adjust parameters to control the temperature within +-1 degrees, humidity +-5% range.
7、Auxiliary output function: Different auxiliary output can be customized according to the needs of users. At present, the controller has five different auxiliary output functions for users to choose.
8、 Wind Turbine Control:By setting the wind turbine control parameters, the wind turbine can be output as high speed and low speed. When the measured temperature is close to the target temperature, it is the low-speed wind turbine output; otherwise, it is the high-speed wind turbine output.
9、Rich peripheral functions: Through RS485 interface, can be connected with U disk controller, or micro printer control board, or computer software connection output data.
10、Power supply: General AC 85-264V input, even in harsh power environment can ensure reliable use,and the export is not affected at all.
11、Display:High definition large digital tube display cycle times, running time, measurement temperature, illumination, user observation data at a glance.