YLQZ111 microcomputer 30 section artificial climate incubator controller

Back to list

Product descriptionTechnical indexApplication fieldDownload

Product features:

1、30 section program control:Microcomputer program control temperature, humidity, six levels of light, can be set up 30 program control. The 30-section program can run several sections at will. After the last section runs, it can run repeatedly from the first section, and the number of repeated runs can be set.

2、Power on mode selection:During power-on, you can select the power-on state to stop.Either from the first section or from the last power failure.

3、Make an appointment to boot:If you need to start the system automatically after a period of time, you can enable the scheduled startup function.

4、Rich protection function: 2 level temperature alarm protection, humidification condition protection, refrigeration protection, temperature fault alarm or measurement beyond the range of alarm, etc., perfect protection function to ensure the safe operation of the experiment without accidents.

5、Balanced or start-stop control:Through parameter setting, you can select balanced temperature and humidity control or start stop temperature and humidity control.Balance type control temperature and humidity can start the temperature or humidity self-tuning to more accurately control the temperature (+-0.1 degree) and humidity (+-1%), balance type has defrosting output options.Compressor refrigeration dehumidification control with independent intellectual property rights start and stop program, regardless of winter or summer, set high temperature and low temperature, high humidity and low humidity, set light intensity and so on,light intensity and so on, the start-stop control basically does not need to adjust parameters to control the temperature within +-1 degrees, humidity +-5% range.

6、Auxiliary output function:Different auxiliary output can be customized according to the needs of users. At present, the controller has 5 different auxiliary output for users to choose.

 

7、Fan control:By setting the fan parameters, the fan can be output as high speed and low speed. When the measured temperature is close to the target temperature, it is the low-speed fan output; otherwise, it is the high-speed fan output.

8、Water level monitoring and automatic water refill function:With water level signal input and optional automatic water refill output.

9、Rich peripheral functions: Through RS485 interface, can be connected with U disk controller, or micro printer control board, or mobile phone APP or computer software output data.

10、Power supply: General ac 85-264V input, even in harsh power environment can ensure reliable use,and the export is not affected at all.

11、Display:Digital tube display temperature, humidity, light column display light intensity, time setting range is 0-99, the unit is hour or minute, the default is hour.